Posted by : Unknown Thursday 26 September 2013

MIXING OF HOT AND COLD WATER CFD


  •  CAD :
    The geometry is a simple 2 inlet pipe with a mixing junction and an outlet. Cold Water enters from one end and combines with hot water coming from the second end at the junction both inlets are velocity inlets and the outlet is pressure outlet set to zero. (NOT A WALL)
  •  MESHING :
    Learned the importance of slicing up the geometry


Unsliced Geometry

Unsliced Geometry Mesh



Sliced up geometry


Sliced up geometry mesh


  •  Running the solution :
    1) check the mesh
    2) Enable the energy equation and k-epsilon models
    3) set the boundary conditions for the inlet and the outlet and also specify their      temperatures
    4)Intialise the solution and run the calclations
  • Results:
    Cold velocity inlet= 0.05m/s hot velocity inlet= 0.05m/s
    Cold water temperature = 300K
    Hot water temperature = 400K